Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
J Chromatogr A ; 1722: 464843, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38574599

RESUMEN

Reversed-phase high performance liquid chromatography (RP-HPLC) is the most widely used chromatographic method. In addition to hydrophobic interactions, additional interactions such as electrostatic interactions may participate in the retention behaviour of an analyte. This makes it possible to use RP-HPLC for many types of analyte. We describe a simple method for separating inorganic anions on a C18 column, in which retention of inorganic anions is almost entirely due to electrostatic interactions. This leads to rapid separations as well as higher theoretical plate numbers. We used 2 mM phosphoric acid containing a low concentration of disodium molybdate as the mobile phase, which allows UV detection of non-UV-absorbing anions. With this method, we determined eight inorganic anions including several non-UV-absorbing anions photometrically at 220 nm. The detection limits of the examined eight inorganic anions calculated at a signal-to-noise ratio of 3 were between 0.3 and 10 µM. The detector response was linear over three orders of magnitude of inorganic anion concentration. The proposed RP-HPLC/UV method was successfully applied to determine inorganic anions in some water samples.


Asunto(s)
Aniones , Cromatografía de Fase Inversa , Molibdeno , Ácidos Fosfóricos , Aniones/química , Molibdeno/química , Ácidos Fosfóricos/química , Cromatografía de Fase Inversa/métodos , Cromatografía Líquida de Alta Presión/métodos , Límite de Detección
2.
Anal Sci ; 40(5): 951-958, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38598048

RESUMEN

Daily monitoring of serum uric acid levels is very important to provide appropriate treatment according to the constitution and lifestyle of individual hyperuricemic patients. We have developed a suspension-based assay to measure uric acid by adding a sample solution to the suspension containing micro-sized particles immobilized on uricase and horseradish peroxidase (HRP). In the proposed method, the mediator reaction of uricase, HRP, and uric acid produces resorufin from Amplex red. This resorufin is adsorbed onto enzyme-immobilized micro-sized particles simultaneously with its production, resulting in the red color of the micro-sized particles. The concentration of resorufin on the small surface area of the microscopic particles achieves a colorimetric analysis of uric acid with superior visibility. In addition, ethanol-induced desorption of resorufin allowed quantitative measurement of uric acid using a 96-well fluorescent microplate reader. The limit of detection (3σ) and RSD (n = 3) were estimated to be 2.2 × 10-2 µg/mL and ≤ 12.1%, respectively. This approach could also be applied to a portable fluorometer.


Asunto(s)
Colorimetría , Enzimas Inmovilizadas , Fluorometría , Peroxidasa de Rábano Silvestre , Urato Oxidasa , Ácido Úrico , Ácido Úrico/sangre , Ácido Úrico/química , Ácido Úrico/análisis , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Urato Oxidasa/química , Urato Oxidasa/metabolismo , Peroxidasa de Rábano Silvestre/química , Peroxidasa de Rábano Silvestre/metabolismo , Tamaño de la Partícula , Humanos , Suspensiones , Oxazinas/química
5.
Anal Sci ; 39(4): 589-600, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36749561

RESUMEN

An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover trace elements under high-flow-rate conditions. For accurately and precisely determining trace elements, even with a rough control of the sample and eluent flow volumes, an internal standardization technique was employed for the solid-phase extraction and separation. A recovery test of the deionized water-based sample solution was conducted using this system, and good results, with a recovery of 92% or higher, were obtained for 11 elements (Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, Ti, V, and Zn). Eight elements present in certified groundwater and wastewater reference materials (ES-L-1 and EU-L) were separated and preconcentrated using this system. Almost all the determined values were within their tolerance intervals, and no significant differences were observed between the determined and certified values, demonstrating the validity of this method. The time required for the separation and preconcentration using approximately 100 mL of the sample solution was approximately 6.5 min, and theoretically, the system could be used to preconcentrate 17 samples in an hour because extraction and elution could be conducted simultaneously using two cartridges packed with the chelating resin. Using this system equipped with cartridges packed with CM-PEI600 resin, solid-phase extraction and the separation of multiple elements were performed simultaneously, automatically, and rapidly, enabling the accurate and precise determination of trace elements in environmental water and inorganic salts even by rapidly flowing the sample solutions using peristaltic pumps. Compared to NOBIAS Chelate PA-1, a commercially available chelating resin, the CM-PEI600 resin can recover trace elements even under an extremely high flow rate of approximately 50 mL min-1.

6.
Anal Sci ; 39(3): 375-381, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36577893

RESUMEN

Hydrophilic interaction chromatography (HILIC)-type sorbents were newly developed for the solid-phase extraction (SPE) of polar compounds. Two methacrylate-base resins with different cross-linking monomers and pore properties were synthesized, and three polyethyleneimines (PEIs) with different molecular weights were modified onto each base resin. In both cases, PEIs with a molecular weight of 10,000 (PEI-10,000) exhibited the highest adsorption properties for polar compounds (uracil, uridine, adenosine, cytidine, and guanosine). To control the water-enriched layer at the surface of the PEI-10,000-modified sorbents, the additive amount of PEI-10,000 in the modified reaction was also optimized. When 10 times the amount of PEI-10,000 to each base resin was added, an improvement in adsorption property was observed. Moreover, the use of a nonaqueous sample solution (100% acetonitrile) during the sample loading process drastically improved adsorption, especially for uracil (about 80%) and adenosine (100%). These results indicate that the formation of a strong water-enriched layer at the surface of sorbents with an effective expression of hydrophilic interaction was an important factor in the adsorption properties of polar compounds in HILIC mode-SPE.

7.
Anal Sci ; 39(5): 749-754, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36001293

RESUMEN

Here, we describe novel, chemically cross-linked, self-molding particulate polymer sorbents that are utilized as a molding-type solid-phase extraction medium (M-SPEM), which exhibits high permeability and rigidness. To fabricate such M-SPEM, first, polyethyleneimine (PEI)-modified reversed-phase (RP)-type particulate sorbents were synthesized, thereafter, they were chemically cross-linked by a polymer having many epoxy groups together with additional PEI. By optimizing the binding conditions of the particulate sorbents, the resultant M-SPEM has almost the same adsorption properties as the corresponding unmolded particulate sorbent for some polar (e.g., uracil and adenine) compounds. The binding technique proposed here is expected to facilitate the fabrication of molding-type sorbents and improve the performance of the SPE procedure.

8.
Eur J Vasc Endovasc Surg ; 64(4): 367-376, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35680042

RESUMEN

OBJECTIVE: The aim of this study was to create prediction models for two year overall survival (OS) and amputation free survival (AFS) after revascularisation in patients with chronic limb threatening ischaemia (CLTI). METHODS: This was a retrospective analysis of prospectively collected multicentre registry data (JAPAN Critical Limb Ischaemia Database; JCLIMB). Data from 3 505 unique patients with CLTI who had undergone revascularisation from 2013 to 2017 were extracted from the JCLIMB for the analysis. The cohort was randomly divided into development (2 861 patients) and validation cohorts (644 patients). In the development cohort, multivariable risk models were constructed to predict two year OS and AFS using Cox proportional hazard regression analysis. These models were applied to the validation cohort and their performances were evaluated using Harrell's C index and calibration plots. RESULTS: Kaplan-Meier estimates of two year OS and AFS post-revascularisation in the whole cohort were 69% and 62%, respectively. Strong predictors for OS consisted of age, activity, malignant neoplasm, chronic kidney disease (CKD), congestive heart failure (CHF), geriatric nutritional risk index (GNRI), and sex. Strong predictors for AFS included age, activity, malignant neoplasm, CKD, CHF, GNRI, body temperature, white blood cells, urgent revascularisation procedure, and sex. Prediction models for two year OS and AFS showed good discrimination with Harrell's C indexes of 0.73 (95% confidence interval [CI] 0.69 - 0.77) and 0.72 (95% CI 0.68 - 0.76), respectively CONCLUSION: Prediction models for two year OS and AFS post-revascularisation in patients with CLTI were created. They can assist in determining treatment strategies and serve as risk adjustment modalities for quality benchmarking for revascularisation in patients with CLTI at each facility.


Asunto(s)
Enfermedad Arterial Periférica , Insuficiencia Renal Crónica , Humanos , Anciano , Recuperación del Miembro/métodos , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/cirugía , Isquemia/diagnóstico , Isquemia/cirugía , Estudios Retrospectivos , Isquemia Crónica que Amenaza las Extremidades , Factores de Riesgo , Insuficiencia Renal Crónica/diagnóstico , Enfermedad Crónica , Resultado del Tratamiento , Medición de Riesgo
9.
Microbiol Immunol ; 66(8): 403-410, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35607844

RESUMEN

While the COVID-19 pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) poses a threat to public health as the number of cases and COVID-19-related deaths are increasing worldwide, the incidence of the virus infection is extremely low in Japan compared with many other countries. To explain this uncommon phenomenon, we investigated the prevalence of naturally occurring ("natural") antibodies, focusing on those of the secretory immunoglobulin A (sIgA) form, reactive with SARS-CoV-2 among Japanese people. One hundred and eighty healthy Japanese volunteers of a wide range of age who had been considered to be unexposed to SARS-CoV-2 participated in this study. Saliva samples and blood samples were collected from all of the 180 participants and 139 adults (aged ≥ 20 years) included therein, respectively. The determination of saliva IgA antibodies, mostly comprising sIgA antibodies, as well as serum IgA and immunoglobulin G antibodies, reactive with the receptor binding domain of the SARS-CoV-2 spike-1 subunit proteins was conducted using an enzyme-linked immunosorbent assay. The major findings were that 52.78% (95% confidence interval, 45.21%-60.25%) of the individuals who had not been exposed to SARS-CoV-2 were positive for saliva IgA antibodies with a wide range of levels between 0.002 and 3.272 ng/mL, and that there may be a negative trend in positivity for the antibodies according to age. As we had expected, a frequent occurrence of assumable "natural" sIgA antibodies reactive with SARS-CoV-2 among the studied Japanese participant population was observed.


Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Anticuerpos Antivirales , COVID-19/epidemiología , Humanos , Inmunoglobulina A , Inmunoglobulina A Secretora , Inmunoglobulina M , Japón/epidemiología , Pandemias , Prevalencia , Saliva
10.
Anal Sci ; 38(2): 307-315, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35314976

RESUMEN

A fabrication method of molding-type solid-phase extraction media (M-SPEM) bound with commercially available adhesive is presented. Six pieces of M-SPEM were prepared by heating each kneaded product of a particulate sorbent and an adhesive inserted into a six-hole cylindrical mold for hardening under an open system and normal pressure. The particulate sorbent contained in M-SPEM was divinylbenzene-based reversed-phase mode solid-phase extractants that we have reported. An examination of several adhesives showed that the moldability of M-SPEM depended on the composition and properties of the adhesive. The optimized procedure can be used to prepare an M-SPEM containing an 85 wt% particulate sorbent (particulate sorbent/adhesive, 100 mg/17 mg; particle diameter, 90-150 µm), and the M-SPEM has a specific surface area of about 500 m2/g. The established procedure in this study can bind particulate sorbents together, which showed almost no reductions in the adsorption property and liquid permeability compared with those of the particulate sorbent.


Asunto(s)
Adhesivos , Extracción en Fase Sólida , Adsorción , Medios de Cultivo
11.
JTCVS Open ; 8: 524-533, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34458874

RESUMEN

OBJECTIVES: The coronavirus disease 2019 pandemic presents in-person exposure risk during surgical education. We aimed to validate the feasibility of fully remote faculty-supervised surgical training sessions focused on coronary artery bypass grafting using a synthetic simulator and online videochat software. METHODS: This observational study organized 24 sessions of 2-hour remote training. Each session involved 3 trainees, 1 faculty member, and 1 host. A total of 70 trainees and 24 faculty members were enrolled. The participants joined the remote sessions via online videochat and performed focused training in coronary artery anastomosis using a commercially available simulator. A survey was conducted to validate the feasibility of the remote sessions. Performance improvement of the trainees who repeatedly participated (n = 13) were analyzed comparing initial and final scores of various performance indicators. RESULTS: All trainees and faculty members were satisfied with the efficacy of the remote session. Additionally, most trainees (79%) and faculty members (95%) agreed that the remote training sessions were equivalent to conventional onsite training seminars. A significant improvement between initial and last sessions was observed in the scoring components of near side (3.4 ± 1.0 vs 4.1 ± 0.9; P = .02), far side (3.3 ± 0.8 vs 3.9 ± 0.8; P = .03), external appearance (3.5 ± 0.8 vs 4.2 ± 0.7; P = .01), and internal appearance (2.8 ± 0.9 vs 4.0 ± 0.9; P = .004). CONCLUSIONS: Faculty-supervised remote surgical training sessions were executed with satisfactory results. This methodology may have important implications for surgical education during the coronavirus disease 2019 pandemic.

12.
Anal Sci ; 37(8): 1147-1156, 2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-33518583

RESUMEN

Internal standardization was applied to the solid-phase extraction of trace elements using the following commercially available aminocarboxylic acid-type chelating resins: InertSep ME-2, NOBIAS Chelate PA-1, and Presep PolyChelate. The concentration of the trace elements in initial sample solution can be calculated by using the ratio of the added amount of the internal standard element, Y, in the initial sample solution to that in the final solution after the solid-phase extraction, which is proportional to the volume of the sample solution passed through the cartridge, and the ratio of the volume of the initial sample solution to that of a blank solution for preparing the calibration curve. In this solid-phase extraction, strict control of the volumes of the sample solution passed through the cartridge and the final solution after the solid-phase extraction is not needed because these are not used in the calculation of the trace element concentration. The solid-phase extraction with the internal standardization using Y could be applied to the separation and preconcentration of some trace elements, namely Cd, Co, Cu, Fe, Ni, Pb, Ti, and Zn in an artificial seawater spiked with the elements and some certified reference materials, EnviroMAT ES-L-1 Ground Water and EU-L-3 Waste Water, without any interference.

13.
Cardiovasc Interv Ther ; 36(4): 506-513, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32989708

RESUMEN

Few data regarding popliteal artery entrapment syndrome (PAES) is available in Japan. In this study, we investigated incidence, diagnosis and treatment of PAES in current vascular practice. A retrospective analysis of all patients with PAES visiting 31 participating institutes between 2003 and 2015 was conducted. Thirty-five limbs (28 patients) were identified during the 13-year study period, and the incidence of PAES was 0.12% of all peripheral artery disease cases revascularized. Mean age was 32.0 ± 16.9 years old, and 60 and more years old was 10.7%. Also, 92.9% were male and 39.3% were athletes. Most frequent initial symptoms were intermittent claudication in 23 limbs (65.7%); 4 limbs (11.4%) had chronic limb-threatening ischemia. CT scan was most frequently (94.3%) used for the diagnostic imaging followed by MRI (45.7%) and duplex ultrasound (45.7%). Stress test such as dorsal flexion during duplex ultrasound was used only in 28.6%. Thirty-two limbs (91.4%) received surgical treatment, including 23 arterial reconstructions (71.9%); there were no major perioperative complications. All patients achieved improvement of their symptoms, and the average ankle brachial index increased from 0.69 ± 0.22 to 1.00 ± 0.14 post-surgery. The average postoperative follow-up period was 26.0 months with only one reintervention during the follow-up. In conclusion, PAES was a rare condition and traditional surgical treatment was solid. However, given a broad spectrum of clinical feature of PAES and less usage of diagnostic duplex ultrasound with stress test, there might be a miss- or delayed diagnosis of PAES even in the current vascular practice.


Asunto(s)
Arteriopatías Oclusivas , Enfermedad Arterial Periférica , Síndrome de Atrapamiento de la Arteria Poplítea , Adolescente , Adulto , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/epidemiología , Arteriopatías Oclusivas/cirugía , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Retrospectivos , Adulto Joven
14.
J Vasc Access ; 22(4): 677-681, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32524884

RESUMEN

We report a new technique called "reimplantation of an artery with a hairpin turn (RAHT)" to reduce excessive vascular access flow. A 73-year-old woman on dialysis consulted us for vascular surgery because of an increased cardiac preload. Chest radiography and echocardiography revealed an excessive shunt flow in the brachial artery (flow rate, 2336 mL/min). Vascular echo-Doppler of the left upper limb showed that the radial artery made a hairpin turn at the arteriovenous fistula (diameter, 9 mm). Diameters of the radial artery proximal and distal to the arteriovenous fistula were 5.4 and 3.7 mm, respectively. We ligated and divided the juxta-anastomosis proximal radial artery and subsequently created an end-to-side anastomosis between the proximal radial artery and the distal radial artery. The anastomosis ostium in the distal radial artery (the recipient) was formed with a 4-mm longitudinal and gently curved incision. We performed RAHT so that the small anastomosis between both arteries and the small diameter of the distal radial artery juxta-anastomosis segment could reduce the vascular access flow. The flow rates in the brachial artery were 500 mL/min just after surgery and 560 mL/min at 2 months after surgery. Postoperative chest radiography and echocardiography confirmed a decrease in cardiac preload. We believe that this RAHT technique could be useful as one of the options to reduce the flow in patients who have excessive vascular access flow with a radial artery that makes a hairpin turn.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Arteria Radial , Anciano , Derivación Arteriovenosa Quirúrgica/efectos adversos , Femenino , Humanos , Arteria Radial/diagnóstico por imagen , Arteria Radial/cirugía , Flujo Sanguíneo Regional , Diálisis Renal , Reimplantación , Resultado del Tratamiento , Grado de Desobstrucción Vascular
15.
Anal Sci ; 36(10): 1185-1190, 2020 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-32999136

RESUMEN

Hydrophilic interaction chromatography (HILIC) has attractive attention for the separation of water-soluble compounds via HPLC. There are, however, few studies on the pretreatment of the HILIC-type solid-phase extraction (SPE) due to the difficulty of obtaining the HILIC-type sorbent. Therefore, the development of HILIC-type sorbents for SPE is essential. In this study, four different hydrophilic copolymers, namely diallylamine-maleic acid copolymer (DAM), diallylamine-acrylamide copolymer (DAA), allylamine-maleic acid copolymer (MAM), and partly methylcarbonylated allylamine acetate copolymer (MAC), were immobilized on glycidyl methacrylate (GMA)-base resin, and their adsorptive properties were evaluated. The results of the physical and adsorptive properties indicated that a balance between the water content of the water-enriched layer on sorbent and the amount of hydrophilic copolymer immobilized on the GMA-base resin was vital for the adsorption in HILIC-type sorbent for SPE.

16.
Anal Sci ; 36(10): 1153-1155, 2020 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-32963200

RESUMEN

The handling of a particulate sorbent for solid-phase extraction is often troublesome because it causes static clinging and scattering. To overcome this problem, a production method for a simple molding-type solid-phase extraction medium (M-SPEM) was developed in this study by using commercially available adhesives. The content of a particulate sorbent can increase to as much as 85 wt% in the M-SPEM. Because of the high content, the proposed M-SPEMs have a higher specific surface area than previous monolithic media.

17.
Talanta ; 217: 121052, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32498914

RESUMEN

We developed hydrophilic interaction chromatography (HILIC)-type sorbents modified with nucleobases for solid phase extraction (SPE). The synthesized hydrophilic base resins were modified by each nucleobase (adenine, guanine, and cytosine). The measurement of the amount of water content indicated that each nucleobase-modified sorbent had a water layer. To evaluate the adsorption properties in the HILIC mode, we chose two nucleobases (uracil and adenine) and four nucleosides (uridine, adenosine, cytidine, guanosine) as water-soluble analytes, which were loaded into an SPE cartridge packed with the nucleobase-modified sorbent. Firstly, 95% acetonitrile (ACN) solutions were used in the process of conditioning and sample loading of the above polar analytes. High recoveries of the analytes were observed in each nucleobase-modified sorbent, and the Diol-type sorbent (no modification with any of the nucleobases) did not adsorb each water-soluble analyte. On the basis of this result, a 98% ACN solution was used during the process of conditioning and sample loading to decrease the concentration of water in the sample, which potentially inhibited the formation of hydrogen bonding between each analyte and the modified nucleobase. Considerable improvements of recoveries were observed in Adenine- and Cytosine-modified sorbents. These results were possibly attributed to the effective expression of hydrogen bonding by decreasing water concentration in the sample solution. Although a non-aqueous (100% ACN) sample solution can be expected to obtain higher recoveries compared with the 98% ACN solution, a decrease in recoveries was observed in Adenine-modified sorbent. From these results, the highest adsorption property was observed in Adenine-modified sorbent using 98% ACN as a sample condition, and the combination of this sample condition and sorbent is effective for high adsorption under HILIC condition. Moreover, we also revealed that a balance between the thickness of water layer and the modification amount of nucleobase is important for retention in the HILIC-type sorbent.

18.
Anal Sci ; 36(5): 583-587, 2020 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-32092733

RESUMEN

New chelating resins immobilizing carboxymethylated polyallylamine (CM-PAA) were prepared by immobilizing PAAs with some molecular weights on methacrylate resins and then carboxymethylating a part of amino groups in the PAAs using various amounts of sodium monochloroacetate. The molecular weight of PAA barely affected both the amount of PAA immobilized on the resin and the relationship between the carboxymethylation (CM) rate and the ratio of the amount of monochloroacetate used in the CM step. The selectivity of CM-PAA resin for solid-phase extraction of trace elements was almost the same as that of a resin immobilizing carboxylymethylated polyethyleneimine; 10 elements, namely Cd, Co, Cu, Fe, Mo, Ni, Pb, Ti, V, and Zn, could be quantitatively recovered over a wide pH range and alkali and alkaline earth elements were scarcely extracted under acidic and neutral conditions. The CM-PAA resin was applicable to the separation and preconcentration of the elements in a certified reference material (Waste Water, EU-L-1) and a real environmental water sample (ground water).

20.
Gen Thorac Cardiovasc Surg ; 68(12): 1457-1460, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31865599

RESUMEN

Infective endocarditis during pregnancy and subsequent cardiac surgery are rare and carry a high mortality risk for both the mother and fetus. We report our experience with a previously healthy, 22-year-old woman affected by acute active mitral endocarditis due to Streptococcus gordonii at the 24th gestational week, who wished to continue with the pregnancy. Due to cardiogenic shock, an intra-aortic balloon pump was inserted. Our patient successfully underwent mitral valve replacement with normothermic high-flow cardiopulmonary bypass and continuous intraoperative fetus monitoring. She delivered a 2524-g baby vaginally at the 38th gestational week. Both the mother and child were confirmed to be doing well at the 1-year follow-up. Although this was the first case, urgent cardiac surgery and a subsequent childbirth went well by prompt decision of each department.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Adulto , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Humanos , Recién Nacido , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...